Adaptive calibration and quality control of smart sensors by Matej Možek; Danilo Vrtačnik; Drago Resnik; Borut Pečar;

By Matej Možek; Danilo Vrtačnik; Drago Resnik; Borut Pečar; Slavko Amon; et al

Show description

Read or Download Adaptive calibration and quality control of smart sensors PDF

Best nonfiction_6 books

Social Exclusion: Short and Long Term Causes and Consequences

The ebook offers a breathtaking method of social exclusion, with emphasis on structural factors (education, healthiness, injuries) and on brief time period motives hooked up with the obstacle which began in 2008. the image rising, in accordance with econometric research, is that the obstacle has widened the chance of social exclusion, from the structural teams, like disabled humans and previously convicted humans, to different teams, just like the younger, unemployed, low expert employees and immigrants, when it comes to source of revenue, poverty, healthiness, unemployment, transition among occupational statuses, participation, resulting in a widening of socio-economic duality.

Additional info for Adaptive calibration and quality control of smart sensors

Sample text

21] N. A. Ellerbroek, M. Brenner, P. , Practice accreditation for radiation oncology: quality is reality. J Am Coll Radiol, (2006). 3(10): p. 787-92. [22] G. W. R. , Radiation oncology practice accreditation: the American College of Radiation Oncology, Practice Accreditation Program, guidelines and standards. Crit Rev Oncol Hematol, (2005). 55(2): p. 93-102. [23] P. A. C. C. , Peer review and performance improvement in a radiation oncology clinic. Qual Manag Health Care, (1999). 8(1): p. 22-8.

Ellerbroek, M. Brenner, P. , Practice accreditation for radiation oncology: quality is reality. J Am Coll Radiol, (2006). 3(10): p. 787-92 [20] R. Ochoa, F. Gome, I. H. Ferreira, F. Gutt and C. E. deAlmeida; CE. Design of a phantom for the quality control of high dose rate 192Ir source in brachytherapy. Radiotherapy and Oncology, (2007). (82), p. 222-228. [21] N. A. Ellerbroek, M. Brenner, P. , Practice accreditation for radiation oncology: quality is reality. J Am Coll Radiol, (2006). 3(10): p.

Ferraz, A. J. M. Khalil, E. H. Martins, G. Menegussi, D. Moreira, J. R. Rocha and M. A. Pinto, Intercomparison of calibration procedures for 192Ir HDR sources in Brazil, (1999). Med. Biol. 44, N31-N38 [17] R. E. deAlmeida Air kerma standard for calibration of well type chambers in Brazil using 192Ir HDR sources and its traceability. Med. Phys. (2009) 36 (3), 953-60. [18] IAEA, Calibration of brachytherapy sources: Guidelines of standardized procedures for the calibration of brachytherapy sources at secondary standard dosimetry laboratories (SSDL) and hospital, Report No TECDOC 1079, IAEA, Vienna, 1999.

Download PDF sample

Rated 4.97 of 5 – based on 28 votes

About admin